| Item |
Inspection |
Frequency |
Action |
| Air Line Filter |
Check for condensation accumulation |
Daily |
Drain Filter bowl as required. |
| Thermocouple Probes |
Check for cleanliness |
Daily |
Clean probes as necessary |
| Temperature Controllers |
Check for proper calibration |
Weekly |
Check process value with temperature
strips. Recalibrate as required. |
| Tracking |
Test photo-eye and regulators for proper operation |
Weekly |
Adjust settings for photo-eye and/or regulators if needed. |
| General |
Cleanliness/Housekeeping |
Weekly |
Clean on and around the machine |
| General |
Cleanliness/Housekeeping |
Monthly |
Remove the two top covers and two side covers. Clean any accumulated
debris using a compressed air gun. |
| Thermocouple Probes |
Functional check |
Quarterly |
Remove thermocouple probes. Clean and polish tips. Reinstall
and adjust as necessary. (Approximately 3/16" required
for tip compression past contract with drum) Recalibrate temperature
controllers as necessary. |
| Motor |
Brushes |
Quarterly |
Visually inspect motor brushes for wear and replace if necessary |
| Tables |
Proper positioning |
Quarterly |
Check for leveling and placement. |